SAIL Ledger estimation methodology
Version 0.1, July 2026. Maintained by SAIL (Sustainable AI Lab).
Principles
Providers do not disclose per-request footprints via their APIs, so any tracking tool must estimate. SAIL Ledger's approach: be transparent about uncertainty, anchor to the best public data, and label every estimate with its confidence basis: disclosed (provider published a figure), measured (independent hardware benchmark on open weights), or modeled (inferred from model size and architecture).
Energy
Per-request IT energy is a linear function of token counts (the approach validated by EcoLogits against hardware measurement):
energy_wh = (wh_per_1k_input × input_tokens/1000
+ wh_per_1k_output × output_tokens/1000) × PUE
Output tokens dominate (autoregressive decoding); input tokens are weighted at ~10% of
output cost per token. Factors live in models.yaml, calibrated to these anchors:
| Anchor | Figure | Source |
|---|---|---|
| Median Gemini text prompt | 0.24 Wh, 0.03 gCO₂e, 0.26 mL | Google technical disclosure, Aug 2025 |
| Average ChatGPT query | 0.34 Wh, ~0.32 mL | OpenAI (Altman), 2025 |
| Llama 3.1 70B response | ~512 J (0.14 Wh) | Univ. of Michigan / ML.energy |
| DeepSeek R1 median response | ~10.6–20.9 Wh (~11k output tokens) | ML.energy Leaderboard v3.0 |
| Token/parameter scaling | linear energy model | EcoLogits (JOSS, 2025) |
Data-center overhead is applied via a PUE multiplier (default 1.3; configurable).
Water
Two components, both scaled from energy:
- On-site (cooling): WUE in L/kWh. Default 1.0 (consistent with Google's implied ~1.08; industry average is ~1.9, best hyperscalers 0.15–0.3).
- Off-site (electricity generation): EWIF in L/kWh. US average ~3.1 L/kWh consumed (Li et al., Making AI Less "Thirsty"). Provider disclosures typically omit this, which is why Ledger reports it separately.
Carbon
co2_g = energy_kWh × grid carbon intensity (gCO₂e/kWh) for the configured region.
Default 396 g/kWh (IEA estimate for data-center electricity, 2024). Presets range from
50 (Nordic hydro) to 560 (coal-heavy APAC). Scope: operational (market-blind, location-based);
embodied hardware and training amortization are excluded (roadmap).
Fuel mix
Energy is decomposed by the regional electricity generation mix (natural gas, coal, nuclear, renewables, other) to show the fossil-fuel share of AI usage directly.
Known limitations
- Closed-model factors are calibrated estimates, not measurements; true per-model values vary with batching, hardware generation, serving stack, and context length.
- Reasoning models bill "thinking" tokens as output tokens. These are captured, but hidden token accounting varies by provider.
- Training, embodied hardware, networking, and end-user devices are excluded (consistent with Google's disclosed scope).
- Grid intensity uses annual regional averages, not marginal or hourly data.
- Image, video and audio generation are out of scope for v0.1.
Sources
- Google, Measuring the environmental impact of AI inference and technical paper (Aug 2025)
- DCD summary of Google's disclosure
- DCD: Altman's 0.34 Wh / 0.000085 gal figures
- ML.energy Leaderboard and v3.0 analysis
- EcoLogits methodology
- Li, Yang, Islam, Ren, Making AI Less "Thirsty" (EWIF)
- EESI: Data Centers and Water Consumption
- EPA GHG Equivalencies Calculator (real-world equivalents)