Research / SAIL Ledger

SAIL Ledger estimation methodology

Version 0.1, July 2026. Maintained by SAIL (Sustainable AI Lab).

Principles

Providers do not disclose per-request footprints via their APIs, so any tracking tool must estimate. SAIL Ledger's approach: be transparent about uncertainty, anchor to the best public data, and label every estimate with its confidence basis: disclosed (provider published a figure), measured (independent hardware benchmark on open weights), or modeled (inferred from model size and architecture).

Energy

Per-request IT energy is a linear function of token counts (the approach validated by EcoLogits against hardware measurement):

energy_wh = (wh_per_1k_input × input_tokens/1000
           + wh_per_1k_output × output_tokens/1000) × PUE

Output tokens dominate (autoregressive decoding); input tokens are weighted at ~10% of output cost per token. Factors live in models.yaml, calibrated to these anchors:

Anchor Figure Source
Median Gemini text prompt 0.24 Wh, 0.03 gCO₂e, 0.26 mL Google technical disclosure, Aug 2025
Average ChatGPT query 0.34 Wh, ~0.32 mL OpenAI (Altman), 2025
Llama 3.1 70B response ~512 J (0.14 Wh) Univ. of Michigan / ML.energy
DeepSeek R1 median response ~10.6–20.9 Wh (~11k output tokens) ML.energy Leaderboard v3.0
Token/parameter scaling linear energy model EcoLogits (JOSS, 2025)

Data-center overhead is applied via a PUE multiplier (default 1.3; configurable).

Water

Two components, both scaled from energy:

  • On-site (cooling): WUE in L/kWh. Default 1.0 (consistent with Google's implied ~1.08; industry average is ~1.9, best hyperscalers 0.15–0.3).
  • Off-site (electricity generation): EWIF in L/kWh. US average ~3.1 L/kWh consumed (Li et al., Making AI Less "Thirsty"). Provider disclosures typically omit this, which is why Ledger reports it separately.

Carbon

co2_g = energy_kWh × grid carbon intensity (gCO₂e/kWh) for the configured region. Default 396 g/kWh (IEA estimate for data-center electricity, 2024). Presets range from 50 (Nordic hydro) to 560 (coal-heavy APAC). Scope: operational (market-blind, location-based); embodied hardware and training amortization are excluded (roadmap).

Fuel mix

Energy is decomposed by the regional electricity generation mix (natural gas, coal, nuclear, renewables, other) to show the fossil-fuel share of AI usage directly.

Known limitations

  • Closed-model factors are calibrated estimates, not measurements; true per-model values vary with batching, hardware generation, serving stack, and context length.
  • Reasoning models bill "thinking" tokens as output tokens. These are captured, but hidden token accounting varies by provider.
  • Training, embodied hardware, networking, and end-user devices are excluded (consistent with Google's disclosed scope).
  • Grid intensity uses annual regional averages, not marginal or hourly data.
  • Image, video and audio generation are out of scope for v0.1.

Sources